Unvented Water Heaters
Product construction and essential components
*50mm on 400L and 500L vessels
Electric immersion heater | 3kw electric immersion heater, 240V, 1ph, Incoloy 825, with thermostat incl. cut-out |
Thermal insulation to limit heat loss | CFC/HCFC free, (ODP=0, GWP=1), 60mm fire retardant insulation* |
Outer casing of hot water tanks | P200 Plastisol |
Inner cylinder stainless steel storage tank | Duplex stainless steel |
Heating coil | High performance, finned |
Indirect thermostat | Twin thermostat with independent reset, 30-70ºC |
Safety device | Factory fitted with 7bar/90ºC pressure & temperature relief valve |
Connections | Secondary return on 175L & above |
Specifications
All other ranges - 3 bar external expansion
Ancillary components 1 year
*Commercial cylinders carry 5 years guarantee
Expansion | WXI - 3 bar internal expansion with the self-sustaining air-gap system |
Pressure test | Tested to 10 bar |
Secondary return | Standard fit on models 175L & above |
Approvals | BBA, CE, WRAS, KIWA, ISO, WRC |
Guarantee | Internal cylinder - 25 years* |
Direct thermostat | Element thermostat, nominal setting 60°C |
Indirect model | 22mm diameter stainless steel high performance coil & outlet with 1 immersion heater |
Direct model | 80L fitted with 1 immersion heater; 130 - 500L fitted with 2 immersion heaters |
Manufacturing | All UK using state-of-the-art robot technology |
Horizontal & slimline | Suitable for roof voids & 450mmØ specification |
Renewables range | Solar, heat pump and buffer vessels |
Unvented hot water tanks with Venturi Technology - No need for external expansion tanks
We use Venturi technology in our unvented systems to reduce a number of issues with expansion in our energy efficient unvented water heaters. The below diagram depicts the current issues:
How Venturi technology works with Rinnai hot water systems
Water drawn from the mains flows through a patented inlet device house at the cold feed of the hot water system. Using fluid dynamics to create negative pressure known as the ‘Venturi effect'. With precision design this configuration draws enough air in with the flow of water to recharge the air gap as the tank is filled and requires minimal ongoing maintenance. The Venturi technology also eliminates the need for additional expansion vessels.
The Venturi technology is available across a variety of sizes of our advanced models within our stainless steel storage tanks. Contact us today to find out more and allow the Rinnai team to help you select the cylinder size for your needs.
Satisfy your projects hot water requirements with our wide range of products
Solar Direct with single coil designed to minimise energy waste and maximise heat transfer.
Size | H | D | I | O | T | IH1 | CR1 | CF1 | Solar Coil Surface Area |
130L | 1043 | 576 | 182 | 221 | 331 | 454 | 212 | 192 | 0.75m2 |
150L | 1235 | 576 | 182 | 285 | 395 | 454 | 212 | 192 | 0.75m2 |
175L | 1370 | 576 | 182 | 397 | 507 | 580 | 212 | 262 | 1.1m2 |
215L | 1666 | 576 | 182 | 440 | 550 | 524 | 212 | 262 | 1.1m2 |
255L | 1884 | 576 | 182 | 440 | 550 | 524 | 212 | 262 | 1.1m2 |
300L | 2150 | 576 | 182 | 450 | 560 | 524 | 212 | 262 | 1.1m2 |
400L | 1522 | 756 | 220 | 350 | 460 | 538 | 250 | 210 | 1.1m2 |
500L | 1896 | 756 | 220 | 385 | 495 | 538 | 250 | 210 | 1.1m2 |
Solar Indirect with twin coil
CR2 | CF2 | Aux Coil Surface Area |
504 | 192 | 0.54m2 |
504 | 192 | 0.54m2 |
574 | 262 | 0.75m2 |
574 | 262 | 0.75m2 |
574 | 262 | 0.75m2 |
574 | 262 | 0.75m2 |
560 | 175 | 0.75m2 |
560 | 175 | 0.75m2 |
Direct with 3 bar external expansion
Size | H | D | I | T | IH1 | IH2 |
80L | 665 | 576 | 182 | 222 | 196 | N/A |
130L | 957 | 576 | 182 | 222 | 196 | 454 |
150L | 1085 | 576 | 182 | 222 | 196 | 463 |
175L | 1242 | 576 | 182 | 222 | 196 | 545 |
215L | 1484 | 576 | 182 | 222 | 196 | 572 |
225L | 1752 | 576 | 182 | 222 | 196 | 648 |
305L | 2028 | 576 | 182 | 222 | 196 | 725 |
400L | 1405 |
756 |
220 | 262 | 235 | 515 |
500L | 1690 | 756 | 220 | 262 | 235 | 660 |
Indirect with 3 bar external expansion
Size | H | D | I | T | IH1 | CR1 | CF1 | Coil Rating |
80L | 665 | 576 | 182 | 222 | 196 | 213 | 88 | 14.6kW |
130L | 957 | 576 | 182 | 222 | 196 | 213 | 193 | 14.6kW |
150L | 1085 | 576 | 182 | 222 | 196 | 213 | 193 | 14.6kW |
175L | 1242 | 576 | 182 | 222 | 196 | 213 | 263 | 20.0kW |
215L | 1484 | 576 | 182 | 222 | 196 | 213 | 263 | 20.0kW |
255L | 1752 | 576 | 182 | 222 | 196 | 213 | 263 | 20.0kW |
305L | 2028 | 576 | 182 | 222 | 196 | 213 | 263 | 20.0kW |
400L | 1405 | 756 | 220 | 262 | 235 | 250 | 245 | 27.0kW |
500L | 1690 | 756 | 220 | 262 | 235 | 250 | 245 | 27.0kW |
Harness solar energy in your commercial setting with Solar Direct with external expansion cylinders
Size | H | D | I | O | T | CR1 | CF1 | SP1 | IH1 | SR | IH2 | SP2 | Solar Coil Surface Area* | Solar Volume |
130L | 958 | 578 | 183 | 226 | 226 | 226 | 193 | 183 | 454 | 325 | 349 | 226 | 0.75m2 | 56L |
150L | 1086 | 578 | 183 | 226 | 226 | 226 | 193 | 183 | 509 | 340 | 402 | 226 | 0.75m2 | 56L |
175L | 1243 | 578 | 183 | 226 | 226 | 226 | 267 | 183 | 584 | 473 | 402 | 226 | 1.1m2 | 69L |
215L | 1485 | 578 | 183 | 226 | 226 | 226 | 267 | 183 | 587 | 665 | 476 | 226 | 1.1m2 | 69L |
255L | 1753 | 578 | 183 | 226 | 226 | 226 | 267 | 183 | 587 | 665 | 476 | 226 | 1.1m2 | 69L |
305L | 2029 | 578 | 183 | 226 | 226 | 226 | 267 | 183 | 587 | 665 | 476 | 226 | 1.1m2 | 69L |
400L | 1405 | 755 | 220 | 260 | 260 | 260 | 210 | 220 | 538 | 615 | 425 | 260 | 1.1m2 | 69L |
500L | 1690 | 755 | 220 | 260 | 260 | 260 | 210 | 220 | 538 | 615 | 425 | 260 | 1.1m2 | 69L |
Solar Indirect with external expansion for commercial buildings and domestic settings
Size | H | D | I | O | T | CR1 | CF1 | SP1 | CR2 | CF2 | IH1 | SR | SP2 | Solar Coil Surface Area | Aux Coil Surface Area | Aux Coil Rating | Solar Volume |
130L | 958 | 578 | 183 | 226 | 226 | 213 | 193 | 183 | 504 | 193 | 454 | 325 | 226 | 0.75m2 | 0.54m2 | 14.6kW | 56L |
150L | 1086 | 578 | 183 | 226 | 226 | 213 | 193 | 183 | 504 | 193 | 454 | 340 | 226 | 0.75m2 | 0.54m2 | 14.6kW | 56L |
175L | 1243 | 578 | 183 | 226 | 226 | 213 | 267 | 183 | 578 | 263 | 530 | 473 | 226 | 1.1m2 | 0.75m2 | 20.0kW | 69L |
215L | 1485 | 578 | 183 | 226 | 226 | 213 | 267 | 183 | 582 | 263 | 530 | 591 | 226 | 1.1m2 | 0.75m2 | 20.0kW | 69L |
255L | 1753 | 578 | 183 | 226 | 226 | 213 | 267 | 183 | 582 | 263 | 530 | 665 | 226 | 1.1m2 | 0.75m2 | 20.0kW | 69L |
305L | 2029 | 578 | 183 | 226 | 226 | 213 | 267 | 183 | 582 | 263 | 530 | 665 | 226 | 1.1m2 | 0.75m2 | 20.0kW | 69L |
400L | 1405 | 755 | 220 | 260 | 260 | 250 | 210 | 220 | 560 | 175 | 510 | 470 | 260 | 1.1m2 | 0.75m2 | 20.0kW | 69L |
500L | 1690 | 755 | 220 | 260 | 260 | 250 | 210 | 220 | 560 | 175 | 510 | 543 | 260 | 1.1m2 | 0.75m2 | 20.0kW | 69L |
Slim Direct with external expansion the ideal space saving solution within a commercial setting
Size | H | D | I | T | IH1 | IH2 |
100L | 1044 | 515 | 179 | 207 | 193 | 550 |
130L | 1326 | 515 | 179 | 207 | 193 | 643 |
150L | 1466 | 515 | 179 | 207 | 193 | 682 |
175L | 1738 | 515 | 179 | 207 | 193 | 832 |
210L | 2010 | 515 | 179 | 207 | 193 | 1008 |
Slim Indirect with external expansion space saving solutions for a range of properties
Size | H | D | I | T | IH1 | CR1 | CF1 | Coil Rating |
100L | 1044 | 515 | 179 | 207 | 193 | 209 | 320 | 14.6kW |
130L | 1326 | 515 | 179 | 207 | 193 | 209 | 320 | 14.6kW |
150L | 1466 | 515 | 179 | 207 | 193 | 209 | 320 | 14.6kW |
175L | 1738 | 515 | 179 | 207 | 193 | 209 | 400 | 20.0kW |
210L | 2010 | 515 | 179 | 207 | 193 | 209 | 400 | 20.0kW |
Slim Solar Indirect with external expansion the ultimate in renewable space saving efficiency
Size | H | D | I | T | IH1 | CR1 | CF1 | CR2 | CF2 | Solar Coil Surface Area | Aux Coil Surface Area | Aux Coil Rating |
130L | 1326 | 515 | 179 | 207 | 504 | 209 | 245 | 554 | 245 | 0.75m2 | 0.54m2 | 14.6kW |
150L | 1466 | 515 | 179 | 207 | 504 | 209 | 245 | 554 | 245 | 0.75m2 | 0.54m2 | 14.6kW |
175L | 1738 | 515 | 179 | 207 | 609 | 209 | 350 | 659 | 315 | 1.1m2 | 0.75m2 | 20.0kW |
210L | 2010 | 515 | 179 | 207 | 609 | 209 | 350 | 659 | 315 | 1.1m2 | 0.75m2 | 20.0kW |
Ultra-Slim Direct with external expansion - innovations in space saving efficiency
Size | H | D | I | T | IH1 | IH2 |
80L | 1110 | 462 | 165 | 200 | 179 | - |
100L | 1344 | 462 | 165 | 200 | 179 | 664 |
130L | 1716 | 462 | 165 | 200 | 179 | 850 |
150L | 1935 | 462 | 165 | 200 | 179 | 1122 |
165L | 1998 | 462 | 165 | 200 | 179 | 1221 |
Ultra-Slim Indirect with external expansion hot water storage tank
Size | H | D | I | T | IH1 | CR1 | CF1 | Coil |
80L | 1110 | 462 | 165 | 200 | 179 | 195 | 320 | 14.6kW |
100L | 1344 | 462 | 165 | 200 | 179 | 195 | 320 | 14.6kW |
130L | 1716 | 462 | 165 | 200 | 179 | 195 | 320 | 14.6kW |
150L | 1935 | 462 | 165 | 200 | 179 | 195 | 320 | 14.6kW |
165L | 1998 | 462 | 165 | 200 | 179 | 195 | 400 | 20.0kW |
Horizontal Direct - more space saving efficiency from Rinnai
Size | A |
130L | 957 |
150L | 1085 |
175L | 1242 |
215L | 1484 |
255L | 1752 |
305L |
2028 |
Horizontal Indirect available a wide range of properties
Size | A | B | C | Aux Coil m2 |
130L | 957 | 478 | 298 | 0.54 |
150L | 1085 | 543 | 363 | 0.54 |
175L | 1242 | 621 | 371 | 0.75 |
215L | 1484 | 742 | 492 | 0.75 |
255L | 1752 | 876 | 626 | 0.75 |
305L | 2028 | 1014 | 769 | 0.75 |
Heat Pump single coil with external expansion
Size | A | B | C | D | E | F | HP Coil Surface Area* |
150L | 575 | 1085 | 225 | 284 | 182 | 678 | 2m2 |
175L | 575 | 1242 | 225 | 284 | 182 | 720 | 2m2 |
215L | 575 | 1485 | 225 | 284 | 182 | 1035 | 3m2 |
255L | 575 | 1752 | 225 | 284 | 182 | 1035 | 3m2 |
275L | 575 | 1884 | 225 | 284 | 182 | 1035 | 3m2 |
305L | 575 | 2028 | 225 | 284 | 182 | 1035 | 3m2 |
400L | 750 | 1405 | 262 | 303 | 228 | 495 | 4m2 |
500L | 750 | 1690 | 262 | 303 | 228 | 495 | 4m2 |
Standard coil inlet and outlet diameter 28mm (DN25); Other coil sizes available upon request.
NEW - with 28mm inlet & outlet - single coil
Size | A | B | C | D | E | F | HP Coil Surface Area |
400L | 750 | 1405 | 262 | 228 | 228 | 495 | 4m2 |
500L | 750 | 1690 | 262 | 228 | 228 | 495 | 4m2 |
Standard coil inlet and outlet diameter 28mm (DN25); Other coil sizes available upon request.
Heat Pump twin coil with external expansion
Size | A | B | C | D | E | F | G | HP Coil Surface Area | Solar Coil Surface Area |
150L | 575 | 1085 | 856 | 355 | 182 | 105 | 385 | 1.5m2 | 0.54m2 |
175L | 575 | 1242 | 1013 | 460 | 182 | 210 | 525 | 1.5m2 | 0.75m2 |
215L | 575 | 1485 | 1259 | 520 | 182 | 270 | 675 | 2m2 | 1.1m2 |
255L | 575 | 1752 | 1527 | 520 | 182 | 270 | 675 | 2m2 | 1.1m2 |
- | - | - | - | - | - | - | - | - | - |
305L | 575 | 2028 | 1800 | 520 | 182 | 270 | 675 | 2m2 | 1.1m2 |
400L | 750 | 1430 | 1196 | 655 | 276 | 315 | 480 | 3m2 | 2m2 |
500L | 750 | 1715 | 1481 | 655 | 276 | 315 | 720 | 4m2 | 2m2 |
NEW - with 28mm inlet & outlet - twin coil
Size | A | B | C | D | E | F | G | HP Coil Surface Area | Solar Coil Surface Area |
400L | 750 | 1430 | 1196 | 655 | 276 | 315 | 480 | 3m2 | 2m2 |
500L | 750 | 1715 | 1481 | 655 | 276 | 315 | 720 | 4m2 | 2m2 |